Collection — Electric brewing controllers

One element or three vessels.
Set it and brew.

Three controllers for electric brewing: the SV1 for a 120V kettle on a standard 15 A outlet, the SV2 wall panel for one 5,500 W element on 240V, and the new 3V for HERMS and three-vessel breweries. No menus to learn: set the temperature and brew. The SV2 and 3V are hand-built in our Vancouver workshop, and the parts inside are stocked here.

120V or 240V · 1,650 W to 5,500 W

SV2 and 3V hand-built in Vancouver, BC · 2-year warranty

120V or 240VNo programmingPID temperature control1.5" tri-clamp probesL6-30 twist-lock element outletsWall-mount 240V panels2-year warranty
US
Free shipping to the lower 48 over $600Delivered price · no customs, no surprises
2y
2-year warrantyPlus lifetime parts support
BC
Hand-built in VancouverSV2 and 3V wired in our workshop
TL
Twist-lock element plugsNEMA L6-30 on every 240V element outlet
Inside the 3V controller

Three vessels, one wall panel, one 30 A circuit.

The 3V runs a whole HERMS hot side from one panel. Hot liquor, mash and boil each get their own temperature controller and probe, and the Element Select switch sends 5,500 W to whichever vessel needs it.

Top Hot Liquor · Mash · Boil controllers
Key Keyed main switch
Front Pump 1 · Element Select · Pump 2
Side L6-30 element outlets · DIN probe sockets · 120V pump outlets
01

Three controllers, three probes

Hot Liquor, Mash and Boil each have their own display and probe, so you can read every vessel at a glance without moving a probe.

02

Element Select

One switch sends power to the HLT element or the boil kettle element. Running one 5,500 W element at a time keeps the whole brewery on a single 240V, 30 A dryer-style circuit.

03

Two pump outlets

Pump 1 and Pump 2 each have a switch on the panel and a 120V outlet on the side: one for the HERMS recirculation loop, one for transfers and whirlpool.

04

Probes built to last

Three 1.5" tri-clamp 3-wire RTD probes with 50 mm tips on 3 m (10 ft) high-quality shielded cords. They plug into DIN sockets on the panel, so they unplug for cleaning.

Choose your controller

Three controllers. One for every system.

Pick by how many vessels you heat and what outlet you have. A 120V kettle on a standard 15 A outlet: SV1. One 5,500 W element on a 30 A dryer outlet: SV2. Three vessels on one 30 A circuit: 3V.

SV1

120V

PID controller for one 120V element on a standard 15 A outlet. Auto-tune holds mash temperatures to within 0.1 °C, and it can also switch a solenoid valve for fermentation cooling.

Voltage120V, 15 A, up to 1,650 W
ElementsOne
ControlPID with auto-tune and alarms
PlugNEMA 5-15, standard 15 A outlet
FitsUnibräu 10G 120V
From $149 USDSV1 · with or without thermowell Shop SV1 →

SV2

240V

Wall-mount 30 A panel for one 240V element up to 5,500 W. Mash and boil modes, automatic boil-over protection, and switched outlets for a pump and a second 120V accessory. Hand-built in Vancouver.

Voltage240V, 30 A
ElementsOne, up to 5,500 W (L6-30 plug)
ControlMash and boil modes · boil-over protection
PlugNEMA 14-30, dryer outlet
FitsUnibräu 240V, BräuPro, DrainPro kettles
From $650 USDSV2 · with or without thermowell Shop SV2 →
★ New · for HERMS

3V

240V · 3 vessels

Wall-mount panel for three-vessel brewing: Hot Liquor, Mash and Boil controllers with three probes, an element select switch for two 5,500 W elements, and two pump outlets, all on one 30 A circuit. Hand-built in Vancouver.

Voltage240V, 30 A
ElementsTwo outlets, one 5,500 W element at a time
ControlThree controllers: HLT, Mash, Boil · timers · boil-over protection
PlugNEMA 14-30, dryer outlet
FitsHERMS and 3-vessel breweries
From $1,900 USD3V · three probes included Shop 3V →
Matched to your system

Pick by the system you brew on.

Every controller works with standard elements and probes. These are the pairings we build around:

Why our controllers

Built to be repaired, not replaced.

01 · Simple

Set it and brew

No menu trees and no programs to write. Set the temperature, switch on the element, brew.

02 · Hand-built

Wired in Vancouver

The SV2 and 3V are built and tested in our Vancouver workshop before they ship.

03 · Serviceable

Parts in stock

Relays, probes, switches and cords are standard parts we keep in stock, so a failed part is a quick swap, not a new controller.

04 · Safe switching

Contactors on the 240V panels

A contactor physically disconnects the element when it's switched off, so a failed relay can't leave an element powered.

05 · Plugs

Twist-lock element plugs

240V elements connect with NEMA L6-30 twist-lock plugs. Push them fully in and turn to lock; a loose plug is the most common cause of a melted connector.

06 · Warranty

2 years, then parts for life

Two years on our controllers, plus lifetime parts support for as long as you brew on them.

Every controller, side by side

The full line. Pick by vessels and outlet.

All three controllers, with what they run and what they plug into.

Model Voltage Runs Control Outlet Price
SV1 120V · plug-in

120V · up to 1,650 W

One element

PID with auto-tune and alarms

NEMA 5-15 · 15 A From $149 USD Shop →
SV2 240V wall panel

240V · up to 5,500 W

One element (L6-30) · pump + accessory outlets

Mash and boil modes · boil-over protection

NEMA 14-30 · 30 A From $650 USD Shop →
3V 240V wall panel · three vessels New

240V · one 5,500 W element at a time

Two elements (L6-30) · two pumps · three probes included

Three controllers: HLT, Mash, Boil · timers that start at set temperature · boil-over protection · alarm relay

NEMA 14-30 · 30 A From $1,900 USD Shop →

Not sure what your panel can handle? Use the electrical calculator, or send us a photo of your panel.

Start simple · grow into it

Start with one element. Add vessels when you're ready.

Most brewers start on a single vessel and grow. The controllers follow the same path.

Step 1 · 120V kettle

SV1

A Unibräu 10G on a standard kitchen or garage outlet.

From $149

240V→
Step 2 · 240V single vessel

SV2

One 5,500 W element on a dryer outlet: Unibräu 240V, BräuPro and DrainPro kettles.

From $650

Three vessels→
Step 3 · three vessels

3V

HERMS and three-vessel breweries: three controllers, two elements, two pumps, one circuit.

$1,800

Moving from 120V to 240V? Check your panel first with the electrical calculator.

Verified reviews

What our customers are saying

Real reviews from real brewers — pulled live from Judge.me.

Common questions

About our controllers.

Which controller do I need?+

Count the vessels you heat and check your outlet. One 120V kettle on a standard 15 A outlet: the SV1. One 240V element up to 5,500 W on a 30 A dryer-style outlet: the SV2. Three vessels, like our HERMS: the 3V.

What outlet does a 240V controller need?+

The SV2 and 3V plug into a 240V, 30 A NEMA 14-30R receptacle, the same one an electric clothes dryer uses. Any new 240V circuit should be installed by a qualified electrician. Our electrical calculator works out the breaker and wire size.

Do I need a GFCI?+

We recommend GFCI protection on every brewing circuit: a GFCI outlet for the SV1, and a 30 A double-pole GFCI breaker for the SV2 and 3V. A GFCI cuts the power if current leaks to ground, which a regular breaker won't catch, and brew days mix water and electricity.

Can the 3V run two elements at once?+

No. The Element Select switch sends power to the hot liquor tank or the boil kettle, one 5,500 W element at a time. That keeps a whole three-vessel brewery on one 30 A circuit.

Will a controller work with my existing kettle?+

Yes, if your kettle has standard ports. The SV2 and 3V probes mount in a 1.5" tri-clamp port, and the 240V controllers run any 240V element up to 5,500 W with a NEMA L6-30 twist-lock plug. Not sure? Send us a photo.

Can a controller be repaired?+

Yes. They're built from standard parts (relays, switches, probes and cords), and we stock replacements in Vancouver. Contact us and we'll help you find the part.

What's the warranty?+

2 years on the controller, plus lifetime parts support. Temperature probes are consumables with a 6-month warranty.

Still have questions? Talk to a brewer, not a sales rep.

Plug in. Set it. Brew.

Every controller is matched to our elements and probes, and the parts inside are stocked in Vancouver.