Unibräu: Electrical Requirements
Unibräu 10G 120V option
- 3 wire 120V power input
- Nema 5-15 outlet (standard 120V receptacle)

- requires standard household 15A breaker in the electrical panel
- comes with our 120V 1650W brewing element
- 2m (6') power cord included from outlet to SV1 controller
*GFCI receptacle is recommended for added protection. These are standard in most North American kitchens.
*Electrical installations should be performed by a licensed electrician.
Unibräu 10G/20G/30G 240V option
- 4 wire 120V power input
- Nema 14-30 outlet (standard dryer receptacle)
- requires 30A breaker installed in the electrical panel
- comes with our 5500W ultra low watt density brewing element
- 2m (6') power cord included from outlet to SV2 controller
*A 30A GFCI breaker is recommended for extra protection.
*Electrical installations should be performed by a licensed electrician.
International 240V Option
- 3 wire 240V input
- Requires 30A breaker at electrical panel
- bare stripped wire cord end supplied
- comes with our 5500W ultra low watt density brewing element
- 2m (6') power cord included from outlet to SV2 controller
- 240V pump and controller pump outlet supplied
*Electrical installations should be performed by a licensed electrician.
*A 30A GFCI breaker is recommended for extra protection.